Is EQ-5D a valid measure for stroke patients?

Date First Published:
March 22, 2016
Last Updated:
May 23, 2018
Report by:
Alison Smith, Specialist Physiotherapist (Manchester Royal Infirmary)
Search checked by:
Alison Smith, Manchester Royal Infirmary
Three-Part Question:
In [adult stroke patients] is [the EQ-5D] a [valid measure of quality of life]
Clinical Scenario:
We routinely use EQ-5D as a patient experience based outcome for our stroke and neuro service but is it a valid measure for our service?
Neurology was considered to be too wide an area and therefore we narrowed the question to stroke. We did not restrict the question to community dwelling patients as it was felt this would restrict the search.
Search Strategy:
Medline, CINAL and AMED limited to English and humans. The relevant papers reference lists were also checked.
Search Details:
Search terms used; Stroke*, cerebrovascular accident, CVA, Cerebral infarction, Subarachnoid hemorrhag*, subarachnoid haemorrhage*, EQ-5D, quality of life, QoL, Euroqol-5D
Outcome:
Altogether 173 papers were found of which 8 were relevant to the study question.
Relevant Paper(s):
Study Title Patient Group Study type (level of evidence) Outcomes Key results Study Weaknesses
Validity of EQ-5D-5 L in stroke. Golicki, D. Niewada, M. Buczek, J. Karlinska, A. Kobayashi, A. Janssen, M.F. Pickard, S.A. 2015 Poland The study compared the validity of the EQ5D-5L and EQ5D-3L in 408 acute stroke patients during hospitalization Single center cross sectional study (level 2) Modified Rankin Score (mRS) Bartel Index (BI) VAS (Visual Analogue Scale) Moderate to strong correlations were found between 5L and mRS, BI and EQVAS The study supports the EQ-5D-5L as a valid generic health outcome measure in patients with acute stroke. Shows some psycho metric advantages of the EQ-5D-5L in comparison with EQ-5D-3L Quality of life (QoL) questionnaires were administered in a fixed order rather than randomly.
No questionnaires were presented between 5L & 3L. The risk is that memory effects may affect the comparison of the two versions.

Testing for differential item functioning within the EQ-5D. Whynes, D.K. Sprigg, N.Selby, J. Berge, E. Bath, P.M. 2013 UK 1462 patients were recruited approximately 90 days post stroke to assess the presence of differential item functioning within the EQ5D Tested presence of differential item functioning in EQ5D using the data from a large multi-national trial in acute stroke The study mapped the following clinical outcome measures onto the EQ5D: Modified Rankin Score Barthel Index Zung Depression scale It shows it is a sensitive scale in stroke patients but that only UK EQ-5D scores should be compared due to regional variances. The differential item functioning with respect to patient versus proxy responses to the EQ-5D was detectable but the impact on mean index scores insignificant. Inter regional variances were reported and greater proxy variance but this is not isolated to the EQ5D and has also been noted in other QoL measures i.e. SF36 and ascribed to sociocultural differences.
Is the EuroQol a valid measure of health-related quality of life after stroke? Dorman, P.J. Waddell, F. Slattery, J. Dennis, M. Sandercock, P. 1997 Scotland The validity of the EuroQol was assessed in 152 patients with acute stroke.
92 completed questionnaires independently (with mild to moderate stroke) and 60 by proxy (patients with significant motor deficits)
Single group prospective assessment via questionnaire Euro Qol Frenchay activities index HADS (hospital anxiety & depression scale) VAS pain scale Modified single questions Bartel Index GPCS disability index The EuroQol appears to have acceptable concurrent and discriminant validity for the measurement of health related QoL after stroke. -Concurrent validity good- patients who reported problems on EuroQol also reported dysfunction with standard test for that domain -HRQol worst in domains for patients with partial anterior circulation strokes and best in patients with posterior circulation strokes showing discriminant validity. Only used on those >1yr post stroke. Many of our client group are earlier than this.
6 ruled out due to reduced communication
Estimation of minimally important differences in the Eq-5D and SF-6D indices and their utility in stroke Kim, S-K, Kim, S-H. Jo, M-W. Lee, S-I 2015 South Korea 1462 patients were recruited approximately 90 days post stroke to assess the presence of differential item functioning within the EQ5D
The study looked at the minimally important differences in EQ5D and SF-6D indices to explore the responsiveness of EQ-5D and SF 6D in stroke.
487 community subjects who had suffered their first ever or recurrent stroke and were aged 50 years or older.
Anchor based approach using observational longitudinal survey data over 10 month period Modified Rankin Score & Bartel Index (BI) were used as anchors SF36 EQ-5D Minimally important difference (MID) estimates for the EQ-5D ranged from 0.08-0.12 and for SF36 ranged from 0.04-0.014 The MID changes depended on which anchor was used. The study primarily focuses on the MID but also considers the responsiveness of the EQ-5D and SF36. It concluded that EQ-5D can show changes in health state and therefore may be useful in interpretation of intervention effects on Health related QoL The data used was from 2009 but the article published in 2015
Different interviewers did the assessments at different time points but all were trained to reduce variability. This should not impact on the EQ-5D as this is self or by proxy administered.
The article looks at EQ-5D-3L but we use EQ-5D 5L
Validity, reliability and responsiveness of the EQ-5D in German stroke patients undergoing rehabilitation. Hunger, M. Sabariego, C. Stollenwerk, B. Cieza, A. Leidl, R. 2012 Germany Analysis of the validity, reliability and responsiveness of the EQ-5D in German stroke patients. 210 stroke survivors (5.7 weeks post stroke) before and 183 after participating in an education programme while undergoing inpatient rehabilitation Single blind RCT anchor based approach
Patients divided into sub groups
BI 35-65
BI>65
EQ-5D compared with other measures: Stroke impact scale Mobility ADL Physical domain, social HADs The EQ5D showed reasonable validity, reliability and more limited responsiveness in stroke patients. Ceiling effect in higher functioning group (BI>65) Good correlation SIS on mobility (rs=-0.74), self care (rs= -0.65) and usual activities (rs= -0.39) Unable to correlate pain domain as no comparable domain in SIS. Test- retest not responsive to changes in health status in serial assessment of individual patients, people value different domains depending on recovery. Part of another published RCT therefore methodology not included in this paper but referred to original study.
Measuring preference-based quality of life using the EuroQol EQ-5D in patients with cerebral aneurysms. King, J.T. Tsevat, J. Robert, M.S. 2009 USA Validity and reliability of the EQ-5D in 178 Neurosurgical patients with cerebral aneurysms.
55% had survived a SAH
Rank order methods.
Multivariate linear regression.
Glasgow Outcome Scale Rankin Scale Barthel Index Physical performance test scores SF12 HADS EQ5D-3L Construct validity was confirmed by statistically significant association between EQ5D and outcomes Reliablity was demonstrated by Cronbach’s ? of 0.70 No specific pain measure was used to map onto the EQ5D
The study sample was drawn from 1 academic institution. Not all eligible patients enrolled and some did not complete all of the instruments.
Responsiveness of generic health-related quality of life measures in stroke Pickard, S.A. Johnson, J.A. Feeny, D.H. 2004 USA Comparison of the responsiveness of 5 health related quality of life measures in 124 stroke patients within the first 6 months post stroke Observational longitudinal cohort study EQ-5D VAS & index score SF-6D Health Utilities Index (HUI) Mark 2 (HUI2) & Mark 3 (HUI3) BI mRS EQ-Index is more responsive and required smaller sample size to detect MCID than EQ-VAS EQ-5D (index) has a ceiling effect in higher functioning patients Not randomized
Exclusion criteria included aphasia and cognitive impairment and therefore not reflective of our stroke population.
Validation of the EuroQol quality of life questionnaire on stroke victims Pinto, E.B. Maso, L. Vilela, R.N.R. Santos, L.C. Oliveira-Filho, J. 2011 Brasil Validation of the EuroQol on a convenience sample of 67 stroke patients. Convenience sample from stroke clinic EQ5D Modified Barthel Index NIHSS Demonstrates EQ-5D is reproducible and valid EQ5D showed good correlation with both stroke severity (NIHSS, r= -0.404, P<0.001) and degree of impairment on ADL (mBI, r= 0.512 P,0.001) Good interobserver agreement (k>0.60) in all dimensions evaluated P<0.01 Demonstrates a significant correlation exists between QoL and level of function Uses the 3L rather than the 5L
Convenience sample therefore mainly patients who could access outpatients and therefore presenting usually with less severe strokes.
Low quality evidence
Author Commentary:
EQ-5D is not a stroke specific measure but it is the most widely used generic health status questionnaire used in stroke. It’s key limitation is that it does not include questions around speech or cognition which are often issues for stroke patients. Two studies excluded patients with aphasia.
The literature published has established its psychometric properties in stroke patients, reasonable construct, concurrent and discriminant validity, accuracy for predicting outcomes and responsiveness in longitudinal studies. Most of the articles compared it to health state linking this as a reflection of the patient’s quality of life. The studies reviewed often analysed retrospective data collected where the questionnaire had been used as part of a large study.
EQ-5D is designed for self or proxy completion. We did not specify in our question whether the patients were to be able to complete the questionnaire themselves. Many of the studies use proxies and reported it to be reliable when compared to the patients’ health state. We have not used proxies to complete EQ-5D questionnaires but we now could consider using them in our practise.
Our service uses the EQ-5D-5L version as we felt it would be more sensitive to change than the 3L. This was confirmed by the Golicki, D et al 2015 study.
Bottom Line:
Based on the current best evidence there is strong evidence to suggest that the EQ 5D is a valid measure of quality of life.
References:
  1. Golicki, D. Niewada, M. Buczek, J. Karlinska, A. Kobayashi, A. Janssen, M.F. Pickard, S.A. . Validity of EQ-5D-5 L in stroke.
  2. Whynes, D.K. Sprigg, N.Selby, J. Berge, E. Bath, P.M. . Testing for differential item functioning within the EQ-5D.
  3. Dorman, P.J. Waddell, F. Slattery, J. Dennis, M. Sandercock, P. . Is the EuroQol a valid measure of health-related quality of life after stroke?
  4. Kim, S-K, Kim, S-H. Jo, M-W. Lee, S-I . Estimation of minimally important differences in the Eq-5D and SF-6D indices and their utility in stroke
  5. Hunger, M. Sabariego, C. Stollenwerk, B. Cieza, A. Leidl, R. . Validity, reliability and responsiveness of the EQ-5D in German stroke patients undergoing rehabilitation.
  6. King, J.T. Tsevat, J. Robert, M.S.. Measuring preference-based quality of life using the EuroQol EQ-5D in patients with cerebral aneurysms.
  7. Pickard, S.A. Johnson, J.A. Feeny, D.H. . Responsiveness of generic health-related quality of life measures in stroke
  8. Pinto, E.B. Maso, L. Vilela, R.N.R. Santos, L.C. Oliveira-Filho, J. . Validation of the EuroQol quality of life questionnaire on stroke victims