Is prehospital focused abdominal ultrasound useful during triage at mass casualty incidents? n
Date First Published:
February 5, 2007
Last Updated:
July 25, 2013
Report by:
Sebastien Robert, PGY-4 Emergency Medicine Resident (Laval University, Quebec, Canada )
Search checked by:
Marc-Charles Parent, , Laval University, Quebec, Canada
Three-Part Question:
In [victims of a mass casualties incident] is [the addition of prehospital focused abdominal ultrasound to triage better than usual triage alone] at [reducing time to necessary surgery and reducing overall mortality]?
Clinical Scenario:
A bomb explodes in a busy downtown building. When emergency medical care arrives there are 70 casualties on the ground and 50 standing or sitting. The prehospital team knows the START triage system and classifies seven patients as black, 12 as red and 51 as yellow or delayed. The 12 casualties classified as red are transported to the hospital with all the vehicles that were available. You wonder whether using focused abdominal ultrasound would help in further prioritising the transportation of the remainder patients.
Search Strategy:
No BestBETs or relevant critical appraisals were found on this topic at http://www.bestbets.org. No ongoing trials on this topic were registered at http://www.clinicaltrials.gov.
Medline 1950 to present, Embase 1980 to present using NHS Evidence 24/04/2013. Multifile searching:
Medline 1950 to present, Embase 1980 to present using NHS Evidence 24/04/2013. Multifile searching:
Search Details:
((((exp EMERGENCY MEDICAL SERVICES/) OR (prehospital.ti,ab) OR ((pre ADJ hospital).ti,ab) OR (pre-hospital.ti,ab)) AND (((exp ULTRASONOGRAPHY/) OR (ultrasound.ti,ab) OR (ultrasongraph*.ti,ab) OR (echograph*.ti,ab)) AND ((exp WOUNDS AND INJURIES/) OR (exp MULTIPLE TRAUMA/) OR (polytrauma.ti,ab) OR ((multiple ADJ trauma).ti,ab) OR (trauma.ti,ab)))) AND ((exp MASS CASUALTY INCIDENTS/) OR ((mass AND casualt*).ti,ab) OR (exp TERRORISM/) OR (exp DISASTERS/) OR (terrorism.ti,ab) OR (disaster*.ti,ab) OR ((multiple AND victim*).ti,ab))). Limit to English Language 35 unique articles.
The Cochrane Library Issue 3 2013: (MeSH descriptor: [Ultrasonography] explode all trees AND (MeSH descriptor: [Emergency Medical Services] explode all trees OR prehospital:ti,ab,kw (Word variations have been searched))). Thirty-nine records none relevant.
The Cochrane Library Issue 3 2013: (MeSH descriptor: [Ultrasonography] explode all trees AND (MeSH descriptor: [Emergency Medical Services] explode all trees OR prehospital:ti,ab,kw (Word variations have been searched))). Thirty-nine records none relevant.
Outcome:
Five articles addressing the subject were found with the search strategy. One is a letter without pertinent data, one proposes an ultrasound protocol in case of mass casualty without showing original data. The three other studies are shown in the table
Relevant Paper(s):
Study Title | Patient Group | Study type (level of evidence) | Outcomes | Key results | Study Weaknesses |
---|---|---|---|---|---|
Ultrasonographic Applications after Mass Casualty Incident Caused by Wenchuan Earthquake. Dan D, Mingsong L, Jie T, et al. 2010 China | Mass casualty incident: Wenchuan earthquake, China Patients received at a hospital 90 km away from epicentre 587 out of a total of 1386 ultrasounds were performed outside the hospital in the early stage (<72 h) |
Retrospective review | Detection of intra-abdominal injuries | 23 Hemoperitoneum | Retrospective, one hospital Unclear who performed the ultrasound No result shown for early phase only No indeterminate scan Ultrasound performed on only 376% of patients No data on stable versus unstable patients No data on time to definitive treatment |
Detection of pleural effusion | 45 Pleural effusion | ||||
Detection of other injuries | 1 femoral artery | ||||
Time spent for ultrasound | Range : 2-4 min | ||||
Sonographic Screening of Mass Casualties for Abdominal and Renal Injuries Following the 1988 Armenian Earthquake. Sarkisian AE, Khondkarian RA, Amirbekian NM, et al. 1991 Armenia | Mass casualty incident: 1988 Armenian earthquake Triage area organised in the hospital main lobby Ultrasound done by radiologist. 400 of 750 patients admitted during the first 72 h had ultrasound performed |
Retrospective review | Positive ultrasound | 96 positive ultrasound : ( 51 trauma related (35% of abdominal fluid), 45 non trauma related; 304 negative ultrasound | Retrospective review of one hospital No FAST protocol Ultrasound done by radiologist No information on outcome of patients with negative ultrasound CT done in only three of the 400 patients who had ultrasound No data on stable versus unstable patient No data on time to definitive treatment or patient outcome |
Time spent for ultrasound | Average 4 minutes (range : 1-10min) | ||||
Fast Ultrasound as an Adjunct to Triage Using the Start Mass Casualty Triage System: A Preliminary Descriptive System. Sztajnkrycer MD, Baez AA, Luke A. 2006 USA | Modified START triage applied retrospectively to trauma patient in a level 1 trauma centre. Excluding <16 years old, penetrating trauma, isolated burns, fall from standing resulting in isolated injury FAST ultrasound available on 359 patients Ultrasound performed by a supervised senior surgery or emergency medicine resident |
Retrospective cross-sectional study | Positive scan in subgroup classified as yellow Surgery rate | 20 of 286 Positive and 15 were inconclusive. Six patients with positive FAST underwent surgery | 41% of Patients in the database transferred from another hospital Not in a mass casualty setting Modified START triage applied retrospectively No patient classified as green False positive and false negative rates not shown for yellow subgroup |
Author Commentary:
Although Sarkisian et al1 and Dan et al3 present interesting data on the actual use of ultrasound in the setting of mass casualties, it is not clear from the data whether there was any benefit to patient outcome. Further ultrasound was not performed on scene, but in a premedical area near the hospital. In a model based on patients who had attended a level 1 trauma centre, Sztajnkrycer et al2 showed that some patients who would have been classified as yellow using START had a positive FAST. This study was not done in a mass casualty setting and thus the result cannot be easily extrapolated to a mass casualty incident.
Bottom Line:
The feasibility of prehospital ultrasound in mass casualty incidents has been demonstrated, but there is, as yet, no clear evidence of benefit as part of a triage protocol.
References:
- Dan D, Mingsong L, Jie T, et al. . Ultrasonographic Applications after Mass Casualty Incident Caused by Wenchuan Earthquake.
- Sarkisian AE, Khondkarian RA, Amirbekian NM, et al. . Sonographic Screening of Mass Casualties for Abdominal and Renal Injuries Following the 1988 Armenian Earthquake.
- Sztajnkrycer MD, Baez AA, Luke A. . Fast Ultrasound as an Adjunct to Triage Using the Start Mass Casualty Triage System: A Preliminary Descriptive System.